Electrical high pass (HP) Gaussian filter
Keywords
electrical, unidirectional
Ports
Name | Type |
---|---|
input | Electrical Signal |
output | Electrical Signal |
Properties
General Properties
Name | Default value | Default unit | Range |
---|---|---|---|
name Defines the name of the element. |
HP Gaussian Filter | - | - |
annotate Defines whether or not to display annotations on the schematic editor. |
true | - | [true, false] |
enabled Defines whether or not the element is enabled. |
true | - | [true, false] |
type Defines the element unique type (read only). |
HP Gaussian Filter | - | - |
description A brief description of the elements functionality. |
Electrical high pass (HP) Gaussian filter | - | - |
prefix Defines the element name prefix. |
HPF | - | - |
model Defines the element model name. |
- | - | - |
library Defines the element location or source in the library (custom or design kit). |
- | - | - |
local path Defines the local path or working folder $LOCAL for the element. |
- | - | - |
url An optional URL address pointing to the element online help. |
- | - | - |
Standard Properties
Name | Default value | Default unit | Range |
---|---|---|---|
cutoff frequency The 3-dB cutoff frequency of the filter (full with at half maximum, FWHM). |
0.75 * %bitrate% | Hz | (0, +∞) |
order Defines the filter order. |
1 | - | [1, 10] |
insertion loss Defines the insertion loss (attenuation). |
0 | dB | [0, +∞) |
Numerical/Digital Filter Properties
Name | Default value | Default unit | Range |
---|---|---|---|
single tap filter Defines whether or not to use a single tap digital filter to represent the element transfer function in time domain. |
false | - | [true, false] |
number of taps estimation Defines the method used to estimate the number of taps of the digital filter. |
fit tolerance | - | [disabled, fit tolerance, group delay |
filter fit tolerance Defines the mean square error for the fitting function. |
0.001 | - | (0, 1) |
window function Defines the window type for the digital filter. |
rectangular | - | [rectangular, hamming, hanning |
number of fir taps Defines the number of coefficients for digital filter. |
256 | - | [1, +∞) |
maximum number of fir taps Defines the number of coefficients for digital filter. |
4096 | - | [1, +∞) |
filter delay Defines the time delay equivalent to a number of coefficients for digital filter. |
0 | s | [0, +∞) |
initialize filter taps Defines whether to use the initial input signal to initialize filter state values or to set them to zero values. |
false | - | [true, false] |
Diagnostic Properties
Name | Default value | Default unit | Range |
---|---|---|---|
run diagnostic Enables the frequency response of the designed filter implementation and the ideal frequency response to be generated as results. |
false | - | [true, false] |
diagnostic size The number of frequency points used when calculating the filter frequency response. |
1024 | - | [2, +∞) |
Results
Name | Description |
---|---|
diagnostic/response #/transmission | The complex transmission vs. frequency corresponding to the ideal and designed filter. |
diagnostic/response #/gain | The gain vs. frequency corresponding to the ideal and designed filter. |
diagnostic/response #/error | Mean square error comparing the frequency response of the designed filter implementation with the ideal frequency response. |
====================================