Allows observation of constantly varying optical signals in time domain
Keywords
analyzer, optical, unidirectional, bidirectional
Ports
Name | Type |
---|---|
input | Optical Signal |
Properties
General Properties
Name | Default value | Default unit | Range |
---|---|---|---|
name Defines the name of the element. |
Optical Oscilloscope | - | - |
annotate Defines whether or not to display annotations on the schematic editor. |
true | - | [true, false] |
enabled Defines whether or not the element is enabled. |
true | - | [true, false] |
type Defines the element unique type (read only). |
Optical Oscilloscope | - | - |
description A brief description of the elements functionality. |
Allows observation of constantly varying optical signals in time domain | - | - |
prefix Defines the element name prefix. |
OOSC | - | - |
model Defines the element model name. |
- | - | - |
library Defines the element location or source in the library (custom or design kit). |
- | - | - |
local path Defines the local path or working folder $LOCAL for the element. |
- | - | - |
url An optional URL address pointing to the element online help. |
- | - | - |
icon type Defines the icon or element symbol view option. |
small | - | [small, medium |
Standard Properties
Name | Default value | Default unit | Range |
---|---|---|---|
frequency at max power Defines whether or not to automatically set the frequency of operation of the element at the location of the peak with maximum value. |
true | - | [true, false] |
frequency Central frequency of operation. |
193.1 |
THz* *std. unit is Hz |
(0, +∞) |
plot format Defines the plot format for the results. |
power | - | [rectangular, power |
power unit Defines the power unit to plot the results. |
W | - | [W, dBm |
sensitivity The minimum detectable signal power level. |
-100 |
dBm* *std. unit is W |
(-∞, +∞) |
limit time range Enables setting the time range( start/stop) of the analysis. |
false | - | [true, false] |
start time Time instant to start the signal analysis. |
0 | s | [0, +∞) |
stop time Time instant to stop the signal analysis. |
1 | s | [0, +∞) |
Numerical Properties
Name | Default value | Default unit | Range |
---|---|---|---|
convert noise bins Defines if noise bins are incorporated into the signal waveform. |
true | - | [true, false] |
automatic seed Defines whether or not to automatically create an unique seed value for each instance of this element. The seed will be the same for each simulation run. |
true | - | [true, false] |
seed The value of the seed for the random number generator. A value zero recreates an unique seed for each simulation run. |
1 | - | [0, +∞) |
Simulation Properties
Name | Default value | Default unit | Range |
---|---|---|---|
input signal selection Input signal selection option. |
last | - | [last, index |
input signal index The signal index to analyzed. |
1 | - | [1, +∞) |
include delays Defines whether inserted delays should be included as part of the signal or not. |
false | - | [true, false] |
Display Properties
Name | Default value | Default unit | Range |
---|---|---|---|
refresh Defines whether or not to update display and annotations during the simulation. |
true | - | [true, false] |
refresh length Defines how ofter to update the element. This is the minimum number of new data values available at the element input port that will trigger the element update. |
1024 | - | [0, +∞) |
limit display memory Defines whether or not to limit the number of values displayed in the element display. |
true | - | [true, false] |
display memory length This is the number of data values used to update the display and annotations during the simulation. |
2048 | - | [2, +∞) |
Results
Name | Description |
---|---|
sum/signal | The total input signal waveform. Calculated by the sum of the energy of the optical power of the individual modes. |
mode #/signal | The signal waveform corresponding to the individual mode. |
====================================
Implementation Details
The Optical Oscilloscope allows the observation of optical signals' waveform in time domain. Please see the electrical Oscilloscope for more implementation detail information.