Adds a charge monitor to the simulation environment. This command requires the presence of a CHARGE solver region in the objects tree.
Syntax |
Description |
---|---|
addchargemonitor; |
Adds a charge monitor to the simulation environment. This function does not return any data. |
Example
The following script commands will add a 2D y-normal charge monitor to the simulation environment, set its dimension, and enable saving the charge data in a .mat file.
addchargemonitor; set("name","charge"); set("monitor type",6); # 2D y-normal set("x",0); set("x span",5e-6); set("y",0); set("y span",5e-6); set("z",0); set("save data",1); filename = "charge_data.mat"; set("filename",filename);
See Also
List of commands , set , addbandstructuremonitor , addefieldmonitor , addjfluxmonitor