Sets the parameters available in the Far field settings window for far field calculations. To get the available parameters for far field settings, as is shown below, right click on a frequency-domain field monitor and visualize the far field. then select the Far field settings.
|
Syntax |
Description |
---|---|
farfieldsettings("property", value); |
Set the far field filter settings for far field calculations. These settings are applied to all far field projections. Value can be a number or string. This function does not return any data. |
Example
farfieldsettings("far field filter",0.2);farfieldsettings("override near field mesh",1); farfieldsettings("near field samples per wavelength",5);