Adds a time domain EM (electro-magnetic) field monitor to simulation with 'DGTD' solver. A DGTD solver region must be present in the objects tree for this command to work.
Syntax |
Description |
---|---|
addemfieldtimemonitor; |
Adds a time domain EM field monitor to the 'DGTD' solver. This function does not return any data. |
Example 1
The following script commands will add a time domain EM field monitor to the 'DGTD' solver already present in the objects tree and print all available properties of the monitor.
addemfieldtimemonitor; ?set;
Example 2
The following script commands will add a time domain EM field monitor to the 'DGTD' solver, change its name, and assign it to a solid named "2D rectangle".
addemfieldtimemonitor; set("name","time"); set("geometry type","surface"); set("surface type","solid"); set("solid","2D rectangle");
NOTE: The script above assumes that there is already a solid named "2D rectangle" present in the objects tree. |
Example 3
The following script commands will add a 'point' time domain EM field monitor to the 'DGTD' solver and set its location.
addemfieldtimemonitor; set("name","time"); set("geometry type","point"); set("x",1e-6); set("y",0); set("z",0);