Adds a mode expansion monitor to the simulation environment. In MODE an active varFDTD region needs to be present for this command to work.
|
Syntax |
Description |
|---|---|
|
addmodeexpansion; |
Adds a mode expansion monitor to the simulation environment. This function does not return any data. |
| addmodeexpansion(struct_data); |
Adds a mode expansion monitor and set its property using a struct containing "property" and value pairs. See the struct script command page for an example. This function does not return any data. |
Example
The following script commands will add mode expansion and field monitors and then setup some of the expansion monitor properties.
# add monitors
addmodeexpansion;
set("name","mode_expansion");
addpower;
set("name","field");
# set the field monitor to be used by the expansion monitor
select("mode_expansion");
setexpansion("input", "field");
# set the expansion monitor mode solver properties
if (true) {
# select fundamental, fundamental TE or fundamental TM mode
set("mode selection","fundamental mode");
} else {
# alternately, set expansion monitor mode solver properties,
# rather than one of the 'fundamental modes
set("mode selection","user select"); # use the 'user select' option
seteigensolver("use max index",0); # specify a custom value for 'n'
seteigensolver("n",1.1); updatemodes(3); # select the 3rd mode
}
See Also